nerc.ac.uk

Case studies of geothermal system response to perturbations in groundwater flow and thermal regimes

Abesser, Corinna; Schincariol, Robert A.; Raymond, Jasmin; Gil, Alejandro García; Drysdale, Ronan; Piatek, Alex; Giordano, Nicolò; Jaziri, Nehed; Molson, John. 2023 Case studies of geothermal system response to perturbations in groundwater flow and thermal regimes. Groundwater, 61 (2). 255-273. 10.1111/gwat.13086

Before downloading, please read NORA policies.
[thumbnail of Open Access Paper]
Preview
Text (Open Access Paper)
Groundwater - 2021 - Abesser - Case Studies of Geothermal System Response to Perturbations in Groundwater Flow and Thermal.pdf - Published Version
Available under License Creative Commons Attribution 4.0.

Download (12MB) | Preview

Abstract/Summary

Global demands for energy efficient heating and cooling systems coupled with rising commitments toward net zero emissions is resulting in wide deployment of shallow geothermal systems, typically installed to a depth of 100 to 200m, and in the continued growth of the global ground source heat pump (GSHP) market. Ground coupled heat pump (GCHP) systems take up to 85% of the global GSHP market. With increasing deployment of GCHP systems in urban areas coping with limited regulations, there is growing potential and risk for these systems to impact the subsurface thermal regime and to interact with each other or with nearby heat‐sensitive subsurface infrastructures. In this paper, we present three numerical modelling case studies, from the UK and Canada, which examine GCHP systems’ response to perturbation of the wider hydrogeological and thermal regimes. The studies demonstrate how GCHP systems can be impacted by external influences and perturbations arising from subsurface activities that change the thermal and hydraulic regimes in the area surrounding these systems. Additional subsurface heat loads near existing schemes are found to have varied impacts on system efficiency with reduction ranging from <1 % to 8 %, while changes in groundwater flow rates (due to a nearby groundwater abstraction) reduced the effective thermal conductivity at the study site by 13%. The findings support the argument in favour of regulation of GCHP systems or, to a minimum, their registration with records of locations and approximate heat pump capacity – even though these systems do not abstract / inject groundwater.

Item Type: Publication - Article
Digital Object Identifier (DOI): 10.1111/gwat.13086
ISSN: 0017-467X
Additional Keywords: GroundwaterBGS, Groundwater
Date made live: 08 Mar 2021 14:43 +0 (UTC)
URI: https://nora.nerc.ac.uk/id/eprint/529853

Actions (login required)

View Item View Item

Document Downloads

Downloads for past 30 days

Downloads per month over past year

More statistics for this item...