Trick, J.K.; Allen, D.; Shaw, R.; Wealthall, G.P.. 2008 Rapid site characterisation using MIP integrated with a GC-MS-field trial. British Geological Survey, 31pp. (OR/08/005) (Unpublished)
Abstract
This report describes the integration of a portable Gas Chromatograph-Mass Spectrometer (GCMS)
with a Membrane Interface Probe (MIP) site survey system in order to provide on-site
qualitative and quantitative Volatile Organic Compound (VOC) data at the SABRE research cell
in Derbyshire.
The first part of the report gives an introduction to both technologies and a background to the site
conditions. Methodologies and limitations are discussed.
The second part of the report discusses and compares the results obtained from the MIP pushes,
GC-MS analysis of the gas stream and soil samples collected from boreholes drilled adjacent to
the MIP wells. An attempt is made to calibrate the MIP voltage responses using data from the
GC-MS, results are presented both in the text and in the appendices.
A comparison of on-site and off-site soil analysis data is made, highlighting the potential for loss
of volatiles when samples are sent away for analysis. Soil data is also compared to the on-site
down hole gas data.
Information
Programmes:
UNSPECIFIED
Library
Statistics
Downloads per month over past year
Share
![]() |