nerc.ac.uk

Climatological Statistics of Extreme Geomagnetic Fluctuations With Periods From 1 s to 60 min

Rogers, N.C. ORCID: https://orcid.org/0000-0002-8423-6306; Wild, J.A. ORCID: https://orcid.org/0000-0001-8025-8869; Easton, E.F. ORCID: https://orcid.org/0000-0003-3981-0863; Hübert, J. ORCID: https://orcid.org/0000-0003-0526-5609. 2021 Climatological Statistics of Extreme Geomagnetic Fluctuations With Periods From 1 s to 60 min. Space Weather, 19 (11), e2021SW002824. https://doi.org/10.1029/2021SW002824

Before downloading, please read NORA policies.
[img]
Preview
Text (Open Access Paper)
Rogers2021.pdf - Published Version
Available under License Creative Commons Attribution 4.0.

Download (6MB) | Preview

Abstract/Summary

Using a global database of 125 magnetometers covering several decades, we present occurrence statistics for fluctuations of the horizontal geomagnetic field (dBh/dt) exceeding the 99.97th percentile (P99.97) for both ramp changes (Rn) and the root-mean-square (Sn) of fluctuations over periods, τ, from 1 to 60 min and describe their variation with geomagnetic latitude and magnetic local time (MLT). Rates of exceedance are explained by reference to the magneto-ionospheric processes dominant in different latitude and MLT sectors, including ULF waves, interplanetary shocks, auroral substorm currents, and traveling convection vortices. By fitting generalized Pareto tail distributions above P99.97, we predict return levels (RLs) for Rn and Sn over return periods of between 5 and 500 years. P99.97 and RLs increase monotonically with frequency (1/τ) (with a few exceptions at auroral latitudes) and this is well modeled by quadratic functions whose coefficients vary smoothly with latitude. For UK magnetometers providing 1-s cadence measurements, the analysis is extended to cover periods from 1 to 60 s and empirical Magnetotelluric Transfer functions are used to predict percentiles and return levels of the geoelectric field over a wide frequency range (2 × 10−4 to 4 × 10−2 Hz) assuming a sinusoidal field fluctuation. These results help identify the principal causes of field fluctuations leading to extreme geomagnetically induced currents (GIC) in ground infrastructure over a range of timescales and they inform the choice of frequency dependence to use with dBh/dt as a GIC proxy.

Item Type: Publication - Article
Digital Object Identifier (DOI): https://doi.org/10.1029/2021SW002824
Date made live: 20 Jan 2022 10:19 +0 (UTC)
URI: https://nora.nerc.ac.uk/id/eprint/531787

Actions (login required)

View Item View Item

Document Downloads

Downloads for past 30 days

Downloads per month over past year

More statistics for this item...